PCL1200-4H
大功率可程式直流電源供應器
0~400VDC / 0~3ADC,RS-232
RS-485 RS-422 Interface
功能特點
- 最大輸出功率1200W
- 最大電壓從6V到600V,最大電流從2A到200A
- 定電壓和定電流操作,自動CV / CC切換
- 標準2U 19英寸機箱
- 4 1/2位LED電壓和電流顯示
- 恆溫控制風扇,噪音低
- 採用PWM技術,效率高,穩定性高
- 低波紋,高穩定性
- 前面板操作:預設電壓和電流,輸出ON / OFF
- 多重保護:OVP,OTP,UVP和電流限制保護
- 標準接口:RS232,RS485和RS422
- 支援ModBus-RTU命令
產品描述
- PCL系列是高功率輸出開關直流電源,額定功率為1200W。
- PCL系列採用PWM技術,大大降低了開關功耗,因此具有高效率和高穩定性的開關功能。
- PCL系列內置於2U 19英寸標準機箱中。
- 大額定電壓為6V至600V,最大額定電流為2A至200A。
- RS232,RS485和RS422通信接口作為PCL系列的標準部件,為數字控制提供多種通信選擇。
規格
- Model:PCL1200-4H
Output
Rated output
- Voltage:0~400V
- Current:0~3A
- OVP:0~420V
Load regulation
- CV≤0.1%+2LSB,CC≤0.1%+2LSB
Line regulation
- CV≤0.1%+2LSB,CC≤0.1%+2LSB
Ripple & Noise
- ≤100mV
Programming resolution
- OVP:0.1V
- Voltage:0.1V
- Current:0.001A
Display resolution
- Voltage:0.1V
- Current:0.001A
Display accuracy
- Voltage≤0.2%+2LSB, Current ≤0.5%+2LSB
Programming
Interface
- RS232, RS485 and RS422
Commands
- ModBus-RTU
Protection
Over Voltage Protection (O.V.P.)
- Built-in OVP protection with limit of 105% rated output voltage.
- The output will be shut down when OVP is activated.
Over Temperature Protection (O.T.P.)
- Built-in OTP rotection with heat sink temperature limit of 50℃±5%.
- The output will be shut down when OTP is activated.
Under Voltage Protection (U.V.P.)
- Built-in UVP protection with limit of 165Vac.
- The output will be shut down when UVP is activated.
General
Cooling method
- Cooling fan
Operating environment
- 0℃~40℃,10%~80%RH
Storage environment
- -20℃~70℃, 10%~90%RH
Power source
- AC220V±10%, 47~63Hz
Weight
- 11~14kg
Dimensions
- 482Wx88Hx460D mm
訂購資訊
Model |
PCL1200-6 |
PCL1200-12 |
PCL1200-15 |
PCL1200-30 |
PCL1200-60 |
PCL1200-1H |
Output |
Rated output |
Voltage |
0~6V |
0~12V |
0~15V |
0~30V |
0~60V |
0~100V |
Current |
0~200A |
0~100A |
0~80A |
0~40A |
0~20A |
0~12A |
OVP |
0~6.3V |
0~12.6V |
0~15.75V |
0~31.5V |
0~63V |
0~105V |
Load regulation |
CV≤0.2%+2LSB, CC≤0.2%+2LSB |
CV≤0.1%+2LSB, CC≤0.1%+2LSB |
Line regulation |
CV≤0.1%+2LSB, CC≤0.1%+2LSB |
Ripple & Noise |
≤50mV |
≤50mV |
≤50mV |
≤50mV |
≤50mV |
≤100mV |
Programming resolution |
OVP |
0.001V |
0.01V |
0.01V |
0.01V |
0.01V |
0.1V |
Voltage |
0.001V |
0.01V |
0.01V |
0.01V |
0.01V |
0.1V |
Current |
0.1A |
0.1A |
0.01A |
0.01A |
0.01A |
0.01A |
Display resolution |
Voltage |
0.001V |
0.01V |
0.01V |
0.01V |
0.01V |
0.1V |
Current |
0.1A |
0.1A |
0.01A |
0.01A |
0.01A |
0.01A |
Display accuracy |
Voltage≤0.2%+2LSB, Current ≤0.5%+2LSB |
Programming |
Interface |
RS232, RS485 and RS422 |
Commands |
ModBus-RTU |
Protection |
Over Voltage Protection (O.V.P.) |
Built-in OVP protection with limit of
105% rated output voltage.
The output will be shut down when OVP is
activated. |
Over Temperature Protection (O.T.P.) |
Built-in OTP protection with heat sink
temperature limit of 50℃±5%.
The output will be shut down when OTP is
activated. |
Under Voltage Protection
(U.V.P.) |
Built-in UVP protection with limit of
165Vac.
The output will be shut down when UVP is
activated. |
General |
Cooling method |
Cooling fan |
Operating environment |
0℃~40℃,
10%~80%RH |
Storage environment |
-20℃~70℃,
10%~90%RH |
Power source |
AC220V±10%, 47~63Hz |
Weight |
11~14kg |
Dimensions |
482Wx88Hx460D mm |
Model |
PCL1200-150 |
PCL1200-2H |
PCL1200-3H |
PCL1200-4H |
PCL1200-5H |
PCL1200-6H |
Output |
Rated output |
Voltage |
0~150V |
0~200V |
0~300V |
0~400V |
0~500V |
0~600V |
Current |
0~8A |
0~6A |
0~4A |
0~3A |
0~2.4A |
0~2A |
OVP |
0~157.5V |
0~210V |
0~315V |
0~420V |
0~525V |
0~630V |
Load regulation |
CV≤0.1%+2LSB, CC≤0.1%+2LSB |
Line regulation |
CV≤0.1%+2LSB, CC≤0.1%+2LSB |
Ripple & Noise |
≤100mV |
≤100mV |
≤100mV |
≤100mV |
≤200mV |
≤200mV |
Programming resolution |
OVP |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
Voltage |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
Current |
0.001A |
0.001A |
0.001A |
0.001A |
0.001A |
0.001A |
Display resolution |
Voltage |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
0.1V |
Current |
0.001A |
0.001A |
0.001A |
0.001A |
0.001A |
0.001A |
Display accuracy |
Voltage≤0.2%+2LSB, Current ≤0.5%+2LSB |
Programming |
Interface |
RS232, RS485 and RS422 |
Commands |
ModBus-RTU |
Protection |
Over Voltage Protection (O.V.P.) |
Built-in OVP protection with
limit of 105% rated output voltage.
The output will be shut down
when OVP is activated. |
Over Temperature Protection (O.T.P.) |
Built-in OTP protection with
heat sink temperature limit of 50℃±5%.
The output will be shut down
when OTP is activated. |
Under Voltage Protection
(U.V.P.) |
Built-in UVP protection with
limit of 165Vac.
The output will be shut down
when UVP is activated. |
General |
Cooling method |
Cooling fan |
Operating environment |
0℃~40℃, 10%~80%RH |
Storage environment |
-20℃~70℃, 10%~90%RH |
Power source |
AC220V±10%, 47~63Hz |
Weight |
11~14kg |
Dimensions |
482Wx88Hx460D mm |
|
|